TEN 40-4822

TEN 40-4822

  • 厂商:

    TRACOPOWER

  • 封装:

    DIP8 模块

  • 描述:

    隔离模块 直流转换器 2 输出 12V -12V 1.67A,1.67A 36V - 75V 输入

  • 数据手册
  • 价格&库存
TEN 40-4822 数据手册
DC/DC Converter TEN 40 Series, 40 Watt • • • 40 Watt in a 2”x2” package • Over temperature protection, under voltage lockout and Remote On/Off • Shielded metal case with insulated baseplate • Wide 2:1 input voltage range Extended operating temperature range: –40°C to +75°C UL 62368-1 IEC 62368-1 The TEN 40 series is a family of high performance 40W DC/DC converter modules featuring a wide 2:1 input voltage range in a 2"x2" package. Typical applications for these products are battery operated equipment and distributed power architectures in communication and industrial electronics. 3-years product warranty Models Order Code Input Voltage Range TEN 40-1210 TEN 40-1211 TEN 40-1212 TEN 40-1220 TEN 40-1222 TEN 40-1223 TEN 40-1233 TEN 40-1234 TEN 40-1231 TEN 40-1232 TEN 40-2410 TEN 40-2411 TEN 40-2412 TEN 40-2420 TEN 40-2422 TEN 40-2423 TEN 40-2433 TEN 40-2434 TEN 40-2431 TEN 40-2432 TEN 40-4810 TEN 40-4811 TEN 40-4812 TEN 40-4820 TEN 40-4822 TEN 40-4823 TEN 40-4833 TEN 40-4834 TEN 40-4831 TEN 40-4832 9 - 18 VDC (12 VDC nom.) 18 - 36 VDC (24 VDC nom.) 36 - 75 VDC (48 VDC nom.) Output 1 Vnom Imax 3.3 VDC 5 VDC 12 VDC +3.3 VDC +12 VDC +15 VDC +3.3 VDC +3.3 VDC +5 VDC +5 VDC 3.3 VDC 5 VDC 12 VDC +3.3 VDC +12 VDC +15 VDC +3.3 VDC +3.3 VDC +5 VDC +5 VDC 3.3 VDC 5 VDC 12 VDC +3.3 VDC +12 VDC +15 VDC +3.3 VDC +3.3 VDC +5 VDC +5 VDC 8'000 mA 8'000 mA 3'300 mA 8'000 mA 1'800 mA 1'400 mA 6'000 mA 6'000 mA 6'000 mA 6'000 mA 8'000 mA 8'000 mA 3'300 mA 8'000 mA 1'800 mA 1'400 mA 6'000 mA 6'000 mA 6'000 mA 6'000 mA 8'000 mA 8'000 mA 3'300 mA 8'000 mA 1'800 mA 1'400 mA 6'000 mA 6'000 mA 6'000 mA 6'000 mA Output 2 Vnom Imax Output 3 Vnom Imax +5 VDC –12 VDC –15 VDC +12 VDC +15 VDC +12 VDC +15 VDC 8'000 mA 1'800 mA 1'400 mA 400 mA 300 mA 400 mA 300 mA –12 VDC –15 VDC –12 VDC –15 VDC 400 mA 300 mA 400 mA 300 mA +5 VDC –12 VDC –15 VDC +12 VDC +15 VDC +12 VDC +15 VDC 8'000 mA 1'800 mA 1'400 mA 400 mA 300 mA 400 mA 300 mA –12 VDC –15 VDC –12 VDC –15 VDC 400 mA 300 mA 400 mA 300 mA +5 VDC –12 VDC –15 VDC +12 VDC +15 VDC +12 VDC +15 VDC 8'000 mA 1'800 mA 1'400 mA 400 mA 300 mA 400 mA 300 mA –12 VDC –15 VDC –12 VDC –15 VDC 400 mA 300 mA 400 mA 300 mA Efficiency typ. 86 % 86 % 86 % 85 % 85 % 85 % 84 % 84 % 86 % 86 % 87 % 89 % 88 % 86 % 87 % 87 % 85 % 85 % 87 % 87 % 88 % 90 % 89 % 88 % 87 % 87 % 86 % 86 % 88 % 88 % Options TEN-HS3 Note - Optional Heat Sink: www.tracopower.com/products/ten-hs3.pdf - TEN 40-xx20: Dynamic current allocation, 8 A total output current for both outputs together www.tracopower.com September 20, 2023 Page 1 / 6 TEN 40 Series, 40 Watt Input Specifications Input Current - At no load - At full load 12 Vin models: 24 Vin models: 48 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: Surge Voltage Under Voltage Lockout Recommended Input Fuse 12 Vin models: 24 Vin models: 48 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: Input Filter 200 mA typ. 80 mA typ. 50 mA typ. 2'680 mA typ. (3.3 Vout model) 4'065 mA typ. (5 Vout model) 4'065 mA typ. (12 Vout model) 3'415 mA typ. (3.3 / 5 Vout model) 4'400 mA typ. (12 / -12 Vout model) 4'400 mA typ. (15 / -15 Vout model) 3'000 mA typ. (3.3 / 12 / -12 Vout model) 3'000 mA typ. (3.3 / 15 / -15 Vout model) 4'000 mA typ. (5 / 12 / -12 Vout model) 4'000 mA typ. (5 / 15 / -15 Vout model) 1'325 mA typ. (3.3 Vout model) 2'000 mA typ. (5 Vout model) 2'000 mA typ. (12 Vout model) 1'685 mA typ. (3.3 / 5 Vout model) 2'100 mA typ. (12 / -12 Vout model) 2'100 mA typ. (15 / -15 Vout model) 1'500 mA typ. (3.3 / 12 / -12 Vout model) 1'500 mA typ. (3.3 / 15 / -15 Vout model) 1'990 mA typ. (5 / 12 / -12 Vout model) 1'990 mA typ. (5 / 15 / -15 Vout model) 655 mA typ. (3.3 Vout model) 1'000 mA typ. (5 Vout model) 1'000 mA typ. (12 Vout model) 825 mA typ. (3.3 / 5 Vout model) 1'050 mA typ. (12 / -12 Vout model) 1'050 mA typ. (15 / -15 Vout model) 750 mA typ. (3.3 / 12 / -12 Vout model) 750 mA typ. (3.3 / 15 / -15 Vout model) 980 mA typ. (5 / 12 / -12 Vout model) 980 mA typ. (5 / 15 / -15 Vout model) 36 VDC max. (100 ms max.) 50 VDC max. (100 ms max.) 100 VDC max. (100 ms max.) 7 VDC min. / 8 VDC typ. / 8.8 VDC max. 15 VDC min. / 16 VDC typ. / 17.5 VDC max. 32.5 VDC min. / 34 VDC typ. / 35.5 VDC max. 8'000 mA (fast acting) 4'000 mA (slow blow) 2'000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal LC-Type Output Specifications Output Voltage Adjustment Voltage Set Accuracy ±10% (single output and dual symmetric output models only) (By external trim resistor) See application note: www.tracopower.com/overview/ten40 Output power must not exceed rated power! ±1% max. (±5% for triple models, (aux)) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 2 / 6 TEN 40 Series, 40 Watt Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) - Cross Regulation (25% / 100% asym. load) Ripple and Noise (20 MHz Bandwidth) - single output - dual output - triple output Capacitive Load - single output - dual output - triple output Minimum Load - single output - dual output - triple output Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation Overvoltage Protection Transient Response - Response Time single output models: 0.5% max. dual output models: 0.5% max. triple output models: 1% max. 5% max. (aux) single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) triple output models: 2% max. (Output 1) 5% max. (Output 2) 5% max. (Output 3) dual output models: 5% max. triple output models: 1% max. 5% max. (aux) 3.3 Vout: 50 mVp-p typ. (w/ 0.1 μF MLCC) 5 Vout: 50 mVp-p typ. (w/ 0.1 μF MLCC) 12 Vout: 75 mVp-p typ. (w/ 0.1 μF MLCC) 3.3 / 5 Vout: 100 / 100 mVp-p typ. (w/ 1 uF MLCC) 12 / -12 Vout: 120 / 120 mVp-p typ. (w/ 0.1 μF MLCC) 15 / -15 Vout: 150 / 150 mVp-p typ. (w/ 0.1 μF MLCC) 3.3 / 12 / -12 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC) 3.3 / 15 / -15 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC) 5 / 12 / -12 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC) 5 / 15 / -15 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC) 3.3 Vout: 21'000 µF max. 5 Vout: 13'600 µF max. 12 Vout: 2'360 µF max. 3.3 / 5 Vout: 11'000 / 6'800 µF max. 12 / -12 Vout: 1'200 / 1'200 µF max. 15 / -15 Vout: 750 / 750 µF max. 3.3 / 12 / -12 Vout: 13'000 / 330 / 330 µF max. 3.3 / 15 / -15 Vout: 13'000 / 110 / 110 µF max. 5 / 12 / -12 Vout: 6'800 / 330 / 330 µF max. 5 / 15 / -15 Vout: 6'800 / 110 / 110 µF max. 3.3 Vout: 0 % of Iout max. 5 Vout: 0 % of Iout max. 12 Vout: 0 % of Iout max. 3.3 / 5 Vout: 0 % of Iout max. 12 / -12 Vout: 8 % of Iout max. 15 / -15 Vout: 8 % of Iout max. 3.3 / 12 / -12 Vout: 10 % of Iout max. 3.3 / 15 / -15 Vout: 10 % of Iout max. 5 / 12 / -12 Vout: 10 % of Iout max. 5 / 15 / -15 Vout: 10 % of Iout max. ±0.02 %/K max. 25 ms typ. (Power On) 25 ms typ. (Remote On) Continuous, Automatic recovery 150% max. of Iout max. 118 - 125% of Vout nom. (depending on model) 3.9 VDC typ. (3.3 VDC outputs) 6.2 VDC typ. (5 VDC outputs) 15 VDC typ. (12 VDC outputs) 18 VDC typ. (15 VDC outputs) (By Zener diode) 250 µs typ. (25% Load Step) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 3 / 6 TEN 40 Series, 40 Watt Safety Specifications Safety Standards EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/ten40 PD 2 Not mains connected - IT / Multimedia Equipment - Certification Documents Pollution Degree Over Voltage Category EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions External filter proposal: EMS Immunity - Electrostatic Discharge Air: Contact: - RF Electromagnetic Field - EFT (Burst) / Surge Ext. input component: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 55032 class A (with external filter) EN 55032 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) www.tracopower.com/overview/ten40 EN 55024 (IT Equipment) EN 55035 (Multimedia) EN 61000-4-2, ±8 kV, perf. criteria B EN 61000-4-2, ±6 kV, perf. criteria B EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria B EN 61000-4-5, ±1 kV, perf. criteria B 220 μF / 100 V / KY EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating Over Temperature Protection Switch Off Cooling System Remote Control 95% max. (non condensing) –40°C to +75°C +100°C max. –55°C to +125°C Depending on model See application note: www.tracopower.com/overview/ten40 115°C typ. - Operating Temperature - Case Temperature - Storage Temperature - High Temperature - Protection Mode - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability - Input to Output, 60 s - Input to Case, 60 s - Output to Case, 60 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF Natural convection (20 LFM) On: 3.5 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 2.5 mA typ. -0.5 to 0.5 mA 5'000 m max. 450 - 550 kHz (PWM) (500 kHz typ.) (Dual models, 3.3 VDC output) 270 - 330 kHz (PWM) (300 kHz typ.) (other models / outputs) Functional Insulation 1'600 VDC 1'600 VDC 1'600 VDC 1'000 MΩ min. 1'000 pF max. 920'000 h (MIL-HDBK-217F, ground benign) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 4 / 6 TEN 40 Series, 40 Watt Washing Process Environment According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf MIL-STD-810F 7.6 g, 3 axis, 60 min, 20-2000 Hz MIL-STD-810F 40 g, 3 axis, half sine, 11 ms MIL-STD-810F Copper, Nickel plated Non-conductive FR4 (UL 94 V-0 rated) Epoxy (UL 94 V-0 rated) Copper Nickel (2 - 3 µm) Tin (3 - 5 µm), matte Metal Case PCB Mount THD (Through-Hole Device) 2" x 2" Lead-Free Wave Soldering 265°C / 10 s max. 60 g - Vibration - Mechanical Shock - Thermal Shock Housing Material Base Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight Thermal Impedance 9.2 K/W typ. 7.6 K/W typ. (with Heat Sink) www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) 59d98b0b-fdf8-4da8-a96c-627ba766180b - Case to Ambient Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/ten40 All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 5 / 6 TEN 40 Series, 40 Watt Outline Dimensions (0.9) Pinout 2.5 22.9 (0.6) 5.08 (0.2) 3 2 Pin (0.1) 15.24 1 Single 7 6 7.62 4 7.62 7.62 (0.3) (0.3) 5.08 5.08 (0.2) (0.2) (0.3) (2.0) 50.8 (1.8) 45.72 5 10.2 (0.4) 50.8 (2.0) +Vin (Vcc) +Vin (Vcc) Triple 1 +Vin (Vcc) –Vin (GND) –Vin (GND) –Vin (GND) –Vin (GND) +Vin (Vcc) Remote On/Off 4 NC No pin Vout 1 Vout 2 5 –Sense* Vout 1 Common Common 6 +Sense* Common NC Vout 3 7 +Vout Common NC Vout 1 8 –Vout Vout 2 Vout 2 Common 9 Trim Trim Common NC NC: Not connected *Sense line to be connected to the output under regard of polarity (Ø0.04) 8 Ø1.0 9 Dual asymmetric 2 3 Bottom view Dual symmetric 5.6 10.2 (0.22) (0.4) Dimensions in mm (inch) Tolerance: x.xx ±0.05 (x.x ±0.02) Tolerance: x.xxx ±0.25 (x.xx ±0.01) Pin dimension tolerance ±0.10 (0.004) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. September 20, 2023 Page 6 / 6
TEN 40-4822 价格&库存

很抱歉,暂时无法提供与“TEN 40-4822”相匹配的价格&库存,您可以联系我们找货

免费人工找货